Gas analyzers are designed for automatic measurement of concentration of one component (oxygen, hydrogen, carbon dioxide, deuterium) in the air of working area of premises and outdoor processing stations.
Application:
01. Monitoring systems of energy technological processes, petrochemical, chemical industry;
02. Atmosphere monitoring system of hazardous industrial objects СКАПО and with БПС-21М.
Principle of operation - thermomagnetic or thermoconductometric.
Type of gas analyzers - fixed.
Operating position – sensor up.
Basic technical characteristics
Designation |
Measured component |
Measuring range, |
Analyzed medium content |
ИБЯЛ.407111.002-03 |
O2 |
0 – 2 |
oxygen - argon |
-04 |
O2 |
0 – 5 |
oxygen - nitrogen |
-05 |
O2 |
0 – 5 |
oxygen - nitrogen |
-06 |
O2 |
0 – 10 |
oxygen - nitrogen |
-07 |
O2 |
0 – 30 |
oxygen - nitrogen |
-08 |
O2 |
0 – 50 |
oxygen - nitrogen |
-09 |
O2 |
15 – 30 |
oxygen - nitrogen |
-10 |
O2 |
0 – 2 |
oxygen - combustion gas * |
-11 |
O2 |
0 – 5 |
oxygen - combustion gas * |
-12 |
O2 |
0 – 5 |
oxygen - combustion gas * |
-13 |
O2 |
0 – 10 |
oxygen - combustion gas * |
-14 |
O2 |
0,0 – 10 |
oxygen - combustion gas * |
-15 |
O2 |
0,0 – 21 |
oxygen - air |
-16 |
O2 |
0,0 – 30 |
oxygen - air |
-17 |
O2 |
0 – 10 |
oxygen - acetylene |
-18 |
Н2 |
0 – 1 |
hydrogen - nitrogen |
-19 |
Н2 |
0 – 2 |
hydrogen - nitrogen |
-20 |
Н2 |
0 – 3 |
hydrogen - nitrogen |
-21 |
Н2 |
60 – 100 |
hydrogen - nitrogen |
-22 |
Н2 |
0 – 1 |
hydrogen - air |
-23 |
Н2 |
0 – 2 |
hydrogen - air |
-24 |
Н2 |
0 – 3 |
hydrogen - air |
-25 |
Н2 |
0 – 1 |
hydrogen - oxygen |
-26 |
Н2 |
0 – 2 |
hydrogen - oxygen |
-27 |
Н2 |
0 – 3 |
hydrogen - oxygen |
-28 |
Н2 |
50 – 100 |
hydrogen - hydrocarbons |
-29 |
Н2 |
70 – 100 |
hydrogen - hydrocarbons |
-30 |
O2 |
0 – 1 |
oxygen - hydrogen |
-31 |
O2 |
0 – 2 |
oxygen - hydrogen |
-32 |
O2 |
0 – 3 |
oxygen - hydrogen |
-33 |
СO2 |
0 – 10 |
carbon dioxide - nitrogen |
-34 |
СO2 |
0 – 20 |
carbon dioxide - nitrogen |
-35 |
СO2 |
0 – 40 |
carbon dioxide - nitrogen |
-36 |
СO2 |
30 – 50 |
carbon dioxide - nitrogen |
-37 |
СO2 |
40 – 100 |
carbon dioxide - nitrogen |
-38 |
O2 |
0 – 1 |
oxygen - deuterium |
-39 |
O2 |
0 – 3 |
oxygen - deuterium |
-40 |
deuterium |
0 – 1 |
deuterium - oxygen |
-41 |
deuterium |
0 – 3 |
deuterium - oxygen |
-42 |
O2 |
0 – 2 |
oxygen - combustion gas ** |
-43 |
O2 |
0 – 5 |
oxygen - combustion gas ** |
-44 |
O2 |
0 – 10 |
oxygen - combustion gas ** |
-45 |
O2 |
0 – 5 |
oxygen - combustion gas ** |
-46 |
O2 |
0 – 10 |
oxygen - combustion gas ** |
-47 |
Н2 |
80 – 100 |
hydrogen - nitrogen |
-48 |
Н2 |
90 – 100 |
hydrogen - nitrogen |
-49 |
Н2 |
95 - 100 |
hydrogen - nitrogen |
Remarks
* - content of combustion gases:
volume fraction of hydrogen (Н2) – up to 1 %;
volume fraction of methane (СН4) – up to 1 %;
volume fraction of carbon dioxide (СО2) – up to 25 %;
nitrogen (N2) – the rest.
** - content of combustion gases:
volume fraction of hydrogen (Н2) – up to 1 %;
volume fraction of methane (СН4) – up to 1 %;
volume fraction of carbon dioxide (СО2) from 7 to 13 %;
nitrogen (N2) – the rest.
Modifications ИБЯЛ.407111. 002, -47..-49 can be used for monitoring of hydrogen purity in generators.
Technical characteristics of gas analyzers ДАМ
Characteristics |
Values |
Remarks |
Principle of operation |
thermomagnetic |
- versions ИБЯЛ.407111.002, -01 … -17, -42 … -46 |
Output signals |
current output 4 - 20 mА
|
- except ДАМ ИБЯЛ.407111.002, -01, -02) |
Explosion protection marking |
1Exd[ib]IICT6X |
|
Dust and moisture protection degree |
IP54 |
|
Overall dimensions of sensors, not more, mm |
165х130х280 |
|
Weight of sensors, not more, kg |
5,0 |
|