Designed for measurement of О2, СО, СО2, NO, NO2, SO2, H2S, HCl, NH3, Cl2, ΣСН and evaluation of NOx , excess air factor α, СО2 in various processes and systems for environment polluting emissions monitoring.
Application: fuel combustion and process facilities of power, metallurgy, glass, chemical and petrochemical industries, constructional materials manufacturing plants, rail transport.
Gas analyzer type - fixed.
Principle of measurement - electrochemical (on СО2, ΣСН channels – optical absorption).
Operation mode – continuous or cyclic.
Sampling - forced (by means of exterior flow rate pump or gauge pressure).
Procedure of industrial emissions monitoring with the use of АНКАТ-410 has been agreed in FSUE “SRI Atmosphere”.
АНКАТ-410-16 is approved for diesel locomotive and diesel train emission monitoring at environment monitoring stations in accordance with СТ СС ФЖТ ЦТ 09-98 and СТ СС ФЖТ ЦТ 07-99 of FSUE “All-Russian Research and Technology Institute of Railway System of Ministry of Transportation of Russia”.
Basic technical characteristics
Measured component |
Measuring (indicating)range |
Least significant digit |
Part of measuring range where error is rated |
Limits of intrinsic absolute error |
О2 |
(0 – 21) vol.% |
0,1 vol.% |
(0 – 5) vol.% (5 – 21) vol.% |
±0,2 vol.% ±0,4 vol.% |
СО |
(0 – 200) ppm |
1,0 ppm |
(0 – 20) ppm (20 – 200) ppm |
±5,0 ppm ±(5+0,06(Сin-20)) ppm |
СО |
(0 – 2000) ppm |
1,0 ppm |
(0 – 2000) ppm |
±10 ppm or |
СО |
(0 – 0,5) vol.% |
0,001 vol.% |
(0 – 0,5) vol.% |
±5% (fiducial) |
NO |
(0 – 200) ppm |
1,0 ppm |
(0 – 50) ppm (50 – 200) ppm |
±5,0 ppm ±(5+0,1(Сin-50)) ppm |
NO |
(0 – 2000) ppm |
1,0 ppm |
(0 – 100) ppm (100 – 200) ppm |
±10 ppm ±(10+0,1(Сin-100)) ppm |
NO |
(0 – 0,4) vol.% |
0,001 vol.% |
(0 – 0,4) vol.% |
±10% (fiducial) |
NO2 |
(0 – 140) ppm |
1,0 ppm |
(0 – 140) ppm |
±15% (fiducial) |
SO2 |
(0 – 200) ppm |
1,0 ppm |
(0 – 50) ppm (50 – 200) ppm |
±10 ppm ±(10+0,1(Сin-50)) ppm |
SO2 |
(0 – 3000) ppm |
10 ppm |
(0 – 3000) ppm |
±20 ppm or |
H2S |
(0 – 40) mg/m3 |
0,1 mg/m3 |
(0 – 40) mg/m3 |
±2 mg/m3 or ±25%(relative)* |
HCl |
(5 – 30) mg/m3 |
0,1 mg/m3 |
(5 – 30) mg/m3 |
±25%(relative) |
NH3 |
(0 – 150) mg/m3 |
1 mg/m3 |
(0 – 20) mg/m3 (20 – 40) mg/m3 |
±5 mg/m3 ±(5+0,25(Сin-20)) mg/m3 |
NH3 |
(0 – 2000) mg/m3 |
10 mg/m3 |
(0 – 2000) mg/m3 |
±50 mg/m3 or |
Cl2 |
(0 – 25) mg/m3 |
0,01 mg/m3 |
(0 – 25) mg/m3 |
±0,25 mg/m3or |
СО2 |
(0 – 30) vol.% |
0,1 vol.% |
(0 – 30) vol.% |
±5% (fiducial) |
ΣCH |
(0 – 0,05) vol.% |
0,0001 vol.% |
(0 – 0,05) vol.% |
±5% (fiducial) |
Notes: * - the greater value of intrinsic error is taken of the two calculated ones.
Сin - analyte content at gas analyzer inlet.
Range of calculated values
Calculation channel |
Range |
Remarks |
СО2 |
(0 – 25) vol.% |
if gas analyzer has no СО2 measuring channel |
NOX |
(0 – 100) ppm (100 – 3000) ppm |
|
excess air factor λ |
0,5 – 9,99 |
|
СО |
(0 – 6,25) g/N·m3 |
for gas analyzer АНКАТ-410-16 |
NOX |
(0 –0,29) g/N·m3 |
for gas analyzer АНКАТ-410-16 |
ΣСН |
(0 – 0,98) g/N·m3 |
for gas analyzer АНКАТ-410-16 |
Gas analyzersАНКАТ-410 are produced in 16 versions that differ in the list of measured components and calculation channels, and also by quantity of ECHC used.
Gas analyzer versions
Versions |
Designation |
Configuration |
АНКАТ-410-01 |
ИБЯЛ.413252.001 |
2 measuring channels with ECHC (single set), without IRS |
АНКАТ-410-02 |
- 01 |
3 measuring channels with ECHC (single set), without IRS |
АНКАТ-410-03 |
- 02 |
4 measuring channels with ECHC (single set), without IRS |
АНКАТ-410-04 |
- 03 |
5 measuring channels with ECHC (single set), without IRS |
АНКАТ-410-05 |
- 04 |
6 measuring channels with ECHC (single set), without IRS |
АНКАТ-410-06 |
- 05 |
2 measuring channels with ECHC (single set), measuring channel with IRS |
АНКАТ-410-07 |
- 06 |
3 measuring channels with ECHC (single set), measuring channel with IRS |
АНКАТ-410-08 |
- 07 |
4 measuring channels with ECHC (single set), measuring channel with IRS |
АНКАТ-410-09 |
- 08 |
5 measuring channels with ECHC (single set), measuring channel with IRS |
АНКАТ-410-10 |
- 09 |
6 measuring channels with ECHC (single set), measuring channel with IRS |
АНКАТ-410-11 |
- 10 |
2 measuring channels with ECHC (dual redundant set), measuring channel without IRS |
АНКАТ-410-12 |
- 11 |
3 measuring channels with ECHC (dual redundant set), measuring channel without IRS |
АНКАТ-410-13 |
- 12 |
2 measuring channels with ECHC (dual redundant set), measuring channel with IRS |
АНКАТ-410-14 |
- 13 |
3 measuring channels with ECHC (dual redundant set), measuring channel with IRS |
АНКАТ-410-15 |
- 14 |
2 measuring channels with ECHC (dual redundant set) for Cl2, HCl |
АНКАТ-410-16 |
- 15 |
3 measuring channels with ECHC: |
Choose gas analyzer modification according to the desired quantity of components under electrochemical control and requirement of СО2 measurement (IRS).
Note. IRS - СО2 infrared sensor.
Advantages:
01. Display of data on each channel on four-line LCD indicator;
02. Software-controlled alarm thresholds (Thresholds 1 and Threshold 2) on each channel;
03. Selection of fuel type and input of soot index, coefficient of fuel, selection of measurement units, input of date and time with keyboard and via RS232 or RS485;
04. 6 software-controlled relays assigned to actuate from alarms “Threshold 1” and “Threshold 2” on selected measuring channel;
05. Non-volatile memory for storage of up to 1000 measurements;
06. 2 current outputs: type - (0 - 5) or (4 - 20) mA, correspondence to measuring channel – selected via software;
07. RS485 digital output with MODBUS RTU Protocol for data exchange;
08. Function of self-testing with output of data on LCD or via RS232 and RS485 channels.